The Correct Direction to Install Wood Stove Pipe

The Correct Direction to Install Wood Stove Pipe

Wood burning is a great way to save some money on your heating bills and also is enjoyable to sit around and watch the fire. Freestanding wood stoves require double wall or single wall stove pipe to connect the stove to the chimney or chimney pipe. Failure to properly install the stove pipe can cause creosote to leak out of the pipe and can be a very unpleasant experience.

The male end of the stove pipe for wood burning should always point down and/or pointing at the stove. Also, the wood stove pipe should always be inserted into the collar of the wood stove outlet.

This may sound backwards considering the direction in which the flue gas is traveling. Some are concerned that the smoke can leak out of the pipe seams - however it will not. The pressure of the draft will be moving too fast for smoke to work through the seam.

The greater concern is creosote leakage through the wood stove pipe connection points. Creosote can often be in liquid form when the stove pipe is cooling and the fire is dying down. The lower temperature condensation will drip creosote down the pipe. If the male end is incorrectly pointing upwards, liquid formed by condensation will always travel down the path of least resistance, and will eventually drip outside of the pipe just like in this picture. By having the male end pointing down, any drips will fall into the female end of the pipe below and back into the stove to be burned.

Now, you may look at your stove pipe setup and say, "The male ends of my pipes are pointing up and I don't have any problems and it's been working like that for years". If it hasn't happened to leak "yet", it's only a matter of time until it does. Changing the pipe configuration will take the "yet" out of the equation and prevent it from happening entirely.

DIY Center

(AKA ‘The Rockford Files’)

From video tutorials to product walkthroughs, we have a variety of DIY resources just for you! Click the button below to view our entire library.

START LEARNING

Need Help?

We are here to answer all of your questions

1-866-708-2446

OR

CONTACT US

Our 316Ti flexible chimney liner and chimney liner components have passed the rigorous testing at the Underwriters Laboratories with best in class status and are UL Listed. So if you are looking for UL listed chimney liner sold directly to homeowners, then look no further than Rockford Chimney

Customer Testimonials

Back in July you gave me excellent advice re. sizing/purchasing a flue liner for the chimney associated with my wood stove. I'd like to thank you once agai... More

—AE Northfield, MN

A few weeks ago I ordered a chimney liner system for my fireplace insert. Your salesman recommended the liner system plus the insulating blanket. I just wa... More

—AH Happy customer

Just got around to installing my new smooth flexible liner and deluxe terra cotta cap (wow). The quality of your product is second to none. Very pleased an... More

—B.B. from Massachusetts

Thanks so much for the great tech service from Dennis, very knowledgable, friendly and proffessional.Your website is the best, beats your competition by fa... More

—Bill in Knoxville

Sue and Dennis, I received the final part of my order yesterday (the chimney cap that actually fits over the chimney chase). It looks wonderfu... More

—CC, VA

Hello, I was shopping for an fireplace insert and called RCS to ask why they were so much cheaper than my local guy, the reply was " we sell thousand of th... More

—Chris, PA.